TM1 Parameterization Sheet

Created by Hiram Camargo Capozzoli, Modified on Fri, 21 Mar at 11:32 AM by Hiram Camargo Capozzoli

Interface Module Serial Number: 

Date:


MENU
Parameter
Description 
SetPoint
Unit 


ALM
OAL
Oil temperature alarm

ºC
OTP
Trip due to oil temperature

ºC
OTD
Trip delay due to oil temperature

min
WAL
Winding temperature alarm

ºC
WTP
Trip due to winding temperature

ºC
WTD
Trip delay due to winding temperature

min


CNF
AOR
Analog output range

mA
AV1 (op.)
Variable associate with analog output1


FE1
Analog output1 end scale

ºC
IE1
Analog output1 start scale

ºC
AV2 (op.)
Variable associate to analog output2


FE2
Analog output2 end scale

ºC
IE2
Analog output2 start scale

ºC
RL7 (op.)
Relay 7 flag function


RTD
Temperature sensor conection option


SML
PT100 inputs through RTD eletronic simulator


MDT
Maximum temperature difference (option rtd 2x3)

ºC
COM
Serial port


BDR
Serial port baud-rate

Kbps
ADR
Serial communication address


PRT (op.)
Communication Protocol


SUP
Supervision mode


NPW
New menu access password



TRF
OWG
Winding temperature gradient

ºC
TW
Winding time constant

seg
HS+
Hot-spot factor according to ABNT and IEEE standards

ºC
HS*
Hot-spot factor according to IEC standard


2*M
Expoente defined by cooling stage type


TRC
Rated winding current

kA
SCR
TC secondary current of thermal imaging

A


FAN
CNF
NCG
Total number of cooling groups


HYS
Difference between the start and stop temperature 

ºC
HYL (op.)
Difference between the start and stop load percentage

%
FEH (op.)
Cooling stage activation start hour

hora
FEM (op.)
Cooling stage activation start minute

min
TFE(op.)
Cooling stage work time

min
CS1
FC1
Cooling stage 1º activation temperature

ºC

LC1(op.)
Cooling stage 1º activation load

%
CG1
Attaching the cooling group 1 in the 1º forced cooling stage


CG2
Attaching the cooling group 2 in the 1º forced cooling stage


CG3
Attaching the cooling group 3 in the 1º forced cooling stage


CG4
Attaching the cooling group 4 in the 1º forced cooling stage


CS2
FC2
Attaching the cooling group 4 in the 1º forced cooling stage

ºC
LC2(op.)
Cooling stage 1º activation load

%
CG1
Attaching the cooling group 1 in the 2º forced cooling stage


CG2
Attaching the cooling group 2 in the 2º forced cooling stage


CG3
Attaching the cooling group 3 in the 2º forced cooling stage


CG4
Attaching the cooling group 4 in the 2º forced cooling stage



LTC (op.)
TRTSelection of the transformer oil temperature sensor for differential calc.
LT1Selection of LTC1 temperature sensor 
LT2Selection of LTC2 temperature sensor
LT3Selection of LTC3 temperature sensor
FTCTime constant to filtering LTCs temperature differentialmin
ALDTime delay for LTC temperature differentials alarmmin
ASMTemperature margin for automatic alarm settings for LTC temperature differentialsºC
ASTTotal Time For Automatic Alarm Settings For LTC Temperature Differentialshours
AASAutomatic alarm setting for LTC temperature differentials
IDALTCs Instantaneous alarm (consultation or manual adjustment)ºC
FDAAlarm for Filtered LTCºC


LOG (op.)
LGT
Time delay to a new record in memory

min
LGH
Temperature variation to a new record in memory

ºC
RST
Memory reset command



Logo da Treetech no final da página.


Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article